Garbage – Central Chutes

Introducing the future of waste management systems

About Us

In the rapidly growing and highly competitive world of today; high-rise buildings, large apartments serving commercial and residential, and construction buildings have become hallmarks of urban development. This development usually comes with a significantly increased challenge in removing solid waste, refuse or garbage from high-rise buildings with multiple levels.

Certified Expert & Team
Fast & Reliable Services

Standard Garbage Chutes

Segregated Garbage Chutes

InterLocking Garbage Chutes

Linen Chutes

Hall Mark Feature of Central Chutes
  • Central Chutes products are a big step in the right direction for the development of sustainable and greener Metropolitan structures.
  • The central chutes products are a major step in encouraging civic accountability in urban settings.
  • Central chutes products offer incredible savings thanks to simple chutes systems.
  • Central chutes offer the dual benefits of separate collection of waste at a single point.
  • Central chutes offer among others the benefits of cost savings and economic operation.
  • Central Chutes allow convenient collection of different types of waste.
  • The intake holders and central chutes controls are carefully designed to meet safety needs.

Services

Installation and repair

With a dedicated team of Mechanical, Electrical, Plumbing and Civil Engineers, we have a solid workforce to ensure that the installation is done according to the requirements of the site

Cleaning the waste chute.

We provide a cleaning service if and when the customer wishes, as the waste chute cleans regularly due to its frequent use

Spare parts and consumables

Since Waste & Linen Chute has some spare parts that are not readily available in your nearest hardware store

Maintenance contract once in a year

Waste chutes are used to centrally collect waste from buildings. Most waste chutes are built with elbows

Types of Garbage Chutes

Necessitatibus eius consequatur ex aliquid fuga eum quidem sint consectetur velit

Features

  • Central chutes are designed and installed in accordance with the specifications in BS 1703: 2005, NFPA 82, IS 6924: 2001 and NBC 2005.
  • Central chutes are designed for a weather-resistant stainless steel service life.
  • Central chutes are equipped with a disinfection system for automatic interior cleaning. This automatic cleaning of our garbage chute takes place from the garbage bin via a control panel. Central chutes also allow the spraying of disinfectants during internal cleaning.
  • Central chutes have an exhaust system that allows a lower limit of 20 air outlets per hour.
  • The central chutes are equipped with inlet funnels that can withstand a fire resistance of 90 minutes.
  • Central chutes are equipped with self-closing intake holders and fireproof doors for optimum security.
App
App

Where to install

The central chutes can be installed in houses or commercial skyscrapers, hotels, hospitals, etc. The central chutes are ideal for installation in a variety of channels, common entrances, pedestals, stairwells, supply channels, balconies and dry kitchens. Central Chutes are installed in the following places:

  • At ground level; Intake holders must be installed at each level.
  • The average landing level; the intake holder will be installed at the alternative floor.

Uniqueness of Central Chutes

Some key advantages that make central chutes the best product of the waste collection channel:

  • Central chutes provide comfort with minimal human effort in waste disposal
  • Central chutes are designed for best sanitation during waste disposal.
  • The central chutes allow the collection of waste for a skyscraper in a single point.
  • Central chutes are designed for optimal energy efficiency
  • Central chutes can be utilized for separate collection of "dry" and "wet" waste
App

Selection of Central Chutes Size

An important decision when choosing the best waste chutes for residential and commercial multi-storey buildings is the diameter of the waste dump. The size of the waste bag used depends on the amount of waste generated. As a standard; the size of the intake holder is chosen on the basis of the size of the waste bag used for collecting and removing waste in multi-storey buildings. The diameter of the waste chutes is then chosen on the basis of the dimensions of the intake holder. Below are the lists with the diameter of the standard dimensions of the central chutes, based on the size of the intake holders and the type of multi-storey buildings in which it is used.

Building Type Chute Diameter
Residential 400 / 600 mm
Commercial 600 mm
Hotel & Malls 750 mm
Hospitals 750 mm

Material Design for Central Chutes

Some key advantages that make central chutes the best product of the waste collection channel:

  • Stainless steel according to codes SS 430 / SS 304
  • Thickness of the drain channel wall: 1.2, 1.5, 2 mm, depending on the diameter of the central chutes.
  • Based on BS / NFPA codes against fire hazards in multi-storey buildings; Fibres and plastics are excluded from the design of the central chutes.
  • To avoid decomposition failure; galvanized steel is excluded from the central chute design.

Central Chute Salient Features

  • Available in different materials, namely SS304, SS430, Galvanized Iron (GI) and Aluminized steel.
  • High pressure disinfectant sprinklers, adjustable sprinklers for full profile, wide angle in all intake stages
  • Cleaning process via the control panel in the waste room.
  • Exhaust system that allows at least 20 to 40 air changes per hour.
  • 90-minute refractory funnels.
  • Fire cut off door discharge end
  • Available in various diameters and holder sizes (day 450 mm / day 600 mm day 750 mm / day 900 mm, etc.)
  • Fire Sprinklers with a standard reaction at 68 ° C are supplied in the chute.
  • Manual fire doors with automatic chute closure.
App

Segregation By Using Bisorters, Trisorters, Quadrasorters

  • It simplifies the separate collection of waste using a chute with Bi sorter, Tri sorter and Quadra sorter, depending on the type of waste.
  • • Urban regulations for the separation of waste into "dry" (recycled) and "wet" (biodegradable) waste.
  • Central chutes are equipped with a disinfection system for automatic interior cleaning. This automatic cleaning of our garbage chute takes place from the garbage bin via a control panel. Central chutes also allow the spraying of disinfectants during internal cleaning.
  • Fully automatic for one user each.
  • All holders are normally locked.

Operational Sequence

  • Press one of the "Dry" or "Wet" buttons
  • The separate waste dump is converted into the respective "Dry" or "Wet" mode by turning the refuse door into the waste chamber.
  • Work holder unlocked with selected waste indication
  • The disposable bag goes to the right trolley.
  • The automatic closing holders restores the system for later use.
  • Total variation over time of 10 seconds

Sailent Features

Some key advantages that make central chutes the best product of the waste collection channel:

  • One step towards eco-friendly buildings.
  • Collection of a separate rubbish bin in a single point.
  • Horizon offers Bisorters (for two types of waste)
  • Trisorter (for three types of waste)
  • Quadrasorter (for four types of waste)
App

The Block Possibility System Is an Advanced Standard Cooling Version

  • It is designed for the concept "one user at a time"
  • Therefore, only an intake holder can be used at a time.
  • All other entry holders at the floor must remain locked with a busy indicator when a floor is in use.
  • It is important that all floor intake holders remain locked during the cleaning process. This is an important security measure for the management and maintenance team.
  • All holders are automatically closed and fireproof.

Linen Chutes

Hotels and hospitals produce dirty clothes in different floors. This used clothing need to be taken to the laundry to sort and clean. For this reason, linen chutes are planned and installed so that clothes pulled from individual floors are collected in the laundry room.

Linen Chutes Can be Installed In
  • Hotels, Hospitals, Bungalows.
  • Residential buildings.
  • In any channel, accessible from every floor.
Advantages of Central Linen Chutes
  • Ease the total collection of building linen in one place.
  • Removal of linen or clothing easily and safely.
  • Reduces energy consumption.
  • Widely used around the world.
  • Reduces human labour.

InterLocking Linen Chute

Linen chutes are used to remove dirty laundry in hotels, hospitals, service places, bungalows, etc. Users can throw away linen through side entry bins placed on the floor. This enables one-off collection of the entire laundry for additional processing.

Central Chute is a groundbreaking company that offers linen chutes in different materials and different diameters. We offer 90min fireproof chute intake holders.

Linen chutes are always interlocking type, allowing only one user at a time. During one holder in operation, all other holders must remain locked with the BUSY indication.

Sailent Features Central Linen Chute
  • Manufactured and installed in accordance with BS 1703: 2005, NFPA 82.
  • Stainless steel construction resistant to weather.
  • Interlocking of chute: holders can reach one user at a time. The holders remain locked with BUSY indicator for all other floors when a floor is used.
  • Ventilation system for air movements when the vacuum breaks.
  • The intake holders have a fire resistance of 90 minutes.
  • The intake holders can be hinged on the left side.
  • Discharge end fire door D Type.
App

OEM Branding Solution

As a manufacturer of waste management systems for Garbage, Debris & Linen Chutes, we have a comprehensive configuration and staff to handle regular national and international orders. Our committed and enthusiastic team of Design, Engineering, Quality and Technical works 16 hours a day, sometimes in several shifts, to ensure that we deliver the products as promised to our customers.

We offer OEM solutions (Original Equipment Manufacturer) completely. Not only do we offer you new and unique conceptual designs, but we also offer you the same standard we are known for. It is basically our product of European standards with its logo and brand that can be marketed all over the world. We will even help you design your marketing material so you can tell your customers that you have a factory in Europe. You have nothing to worry about because we keep the total confidentiality of the trade

0

Satisfied Clients

9999

Complete Projects

Welding

Components & Safety

Intake Holders

The central chutes intake holders are open at the top and rotate at the lower ends. The intake holders are designed to be fixed with a view of the front wall.

Read More
Floor Frames

The total weight of the central chutes is distributed on each floor. As a result, the floor frames on each floor of the residential or commercial multi-storey buildings are designed to support the central chutes in various custom types

Read More
Sanitation System

The sanitation system designed with the central chutes uses sprinklers with 120 conical profiles attached to the inlet for the purpose of optimal sanitation.

Read More
Garbage Trolley

The central chutes waste trolley can be made of plastic and galvanized steel.

Read More
Intake Holder

he central chute intake holder has a fire resistance of at least 90 minutes.The isolation of the central chute intake holders would ensure that the temperature on the non-ignition side is 121 degrees Celsius.

Read More
Fire Sprinklers

Fire extinguisher sprinklers are designed as a half internal BSP thread (BSP) and can be mounted on the 1 inch wet fire riser protection system.

Read More
Discharge Door C Type

The discharge of the “C” type of the central chute is held by a safety connector located at the top of the slope. In case of an epidemic of fire in the waste;

Read More
Discharge Door D Type

The D-type fire discharge door used for the central chutes is mounted horizontally against gravity by a safety connector. In the event of a fire, the safety connector melts at 79 degrees Celsius,

Read More

Do you have any questions or need help about our expertise?

WhatsApp

OUR PRODUCTS & SERVICES: GARBAGE CHUTES AND CENTRAL CHUTES

Central chutes are designed and installed in accordance with the specifications in BS 1703: 2005, NFPA 82, IS 6924: 2001 and NBC 2005. Central chutes are designed for a weather-resistant stainless steel service life.

Garbage Chutes
The odour control unit is designed for installation in closed-door waste rooms to control or reduce odours in the waste rooms. This odour results from the disintegration of the waste in the tanks at room temperature. Odours can be controlled in several ways
Linen Chutes
The system is used to clean the cylindrical inner surface of the waste chute. This is done regularly to maintain the sanitation in the chute. It is installed on top of the chute and controlled from the control panel
Debris Chutes
Sound Deadener is a tar that looks like a thick paint applied to the outside surface of the chute with an airless gun to dampen the sound of the object falling through the chute
Garbage Chutes
The static waste compactor is driven with a fully automatic hydraulic system at a pressure of 30,000 psi and has an automatic on and off switch
Linen Chutes
Waste management is one of the main problems of modern society. In other words, what should we do with the waste we generate

We Deliver Garbage Chute Solutions On Time with Precision

Central chutes are designed and installed in accordance with the specifications in BS 1703: 2005, NFPA 82, IS 6924: 2001 and NBC 2005. Central chutes are designed for a weather-resistant stainless steel service life.

Office Address
123 Street, New York, USA

Office Time
Mon-Sat 09am-5pm, Sun Closed